Time:2023-02-09 Views:820
1. The design height of the high rod light rod on the square: 25 meters, the light pole is an octagonal or duplex cone -shaped rod body, divided into three sections, from top to bottom: 6mm, 8mm, 10mm, upper caliber: 280mm, lower caliber: 560mm, the maximum wind resistance capacity can reach 6 0m/s. It is composed of 3 sections, with a high -quality steel disk flange diameter of 950mm and 25mm thick.
2. The main rod and bracket of the high pole light are formed by high -strength high -quality steel plates through a large bending machine. The buried arc is formed automatically. Ensure that the appearance of 30 years has no corrosion.
3. The high -rod light electric drop system is composed of Shanghai Libo brand electric motor, golden altar rolling machine, hot -dip zinc -steel wire rope and rubber cable. The light rod is installed in the body with a drop speed of 3 to 5 meters per minute.
4. High -rod lamp -oriented, unloading system consisting of guide wheels and guiding arm to ensure that the lamp dish does not move horizontally during the decrease. When the lamplet is rising, it can automatically fall off the lamp dish and lock it from the hook.
5. The high -rod light lighting appliance system is composed of 12 400 W gold halogen light lamps. It can automatically control the switching time and partial lighting of the switching light through the computer.
6. High rod light lightning protection system: 1.5m long lightning rod is installed on the top of the light, 1m long connecting ground wires with underground foundation and connecting to the underground bolt.
7. The high rod lights are reduced by electric control, so that the lamps can be safely and reliable to be reduced to 2.5m from the ground to facilitate maintenance. The high -rod light manual remote control device has a leading line. The operator can rise at a remote control of the light disk at 5 meters, which can ensure the personal safety of the operator.
8. Relief high -rod light can be equipped with a section of spare cables as needed. When the lamp dish is reduced to the minimum position, one end of the cable is inserted into the socket of the electrical control system, and the other end is inserted into the wiring box on the lamp dish. Power on the lamplet directly and repair the lamp.
9. The sealing level of all lamps in the lower high rod lamp is the IP65 standard to prevent the immersion of dust and rainwater and ensure the service life of light sources and electrical appliances. Lantern materials are generally molded with corrosion resistance.